Problem shooting for W/D auto clean Class H certified vacuum AC150H

AC150H is a Class H auto-clean industrial vacuum, equipped with HEPA (High Efficiency Particulate Air) filters capture fine particles and maintain a high level of air quality. Thanks for the innovate and patent auto clean system, it is wildly be used in construction sites generate huge fine dust, such as concrete grinding, cutting, dry core drilling, ceramic tile cutting, wall chasing,circular saw, sander, plasting etc.

Bersi AC150H are sold to many countries to ease the operator's pain of fine dust harmful and filter clogging.Nowadays, the labor cost is so expensive and time is money for every construction worker. When the machine failed during work, below are some tips to help you to fine out problem soonest.

AC150H Problem Shooting

Issue

Cause

Solution

Note

 

Machine doesn’t start

No Power Check whether the socket is powered  
Fuse on PCB is burned out Replace fuse  
Motor failure Replace a new motor If auto clean works,but the vacuum doesn’t work, It can be determined that it is a motor failure
PCB failure Replace a new PCB If neither auto clean and motor doesn’t work,It can be determined that it is a PCB defective
 

 

Motor runs but poor suction

Airflow adjustable knob is at the minimum position Adjust the knob clock wise with larger airflow  
Non woven dust bag is full Replace dust bag  
Filter clogged Dump the dust in the bin If the operator didn’t use the non woven filter bag,the filters will be buried in the dust when the dustbin is very full,which will cause filter clog
Filter clogged Use the deep clean mode(See the user manual for operation) The dust is sticky in some working,even the deep clean mode can’t get the dust on the filter down,please take out the filters and beat  slightly. Or wash the filters and dry them thoroughly before install.
Filter clogged(Auto clean failure) Check if the drive module and reversing valve assembly can work.If not, replace a new one. Take down the filters, check if the 2 motors in the reversing assembly can work.Normally,they are rotate working every 20 seconds.

1)If one motor works all the time, it’s the problem of the B0042 drive module, change a new one.

2)If one motor doesn’t work at all,but another one works intermittently,it’s the problem failed motor, replace a new B0047-Reversing valve assembly of this failed motor.

 

Dust blown from motor

Improper installation

 

Re-install the filter tightly  
Filter damaged Replace a new filter  
Motor abnormal noise Motor failure Replace a new motor  

Any other problem please contact Bersi order service


Post time: Nov-04-2023